E5AR |
(DIGITAL CONTROLLER) |
|
|
|
|
|
Standard Controllers |
Size |
Control type |
Control mode |
Outputs |
Optinal functions |
Model |
(control/transfer) |
Auxilary |
Event |
Serial |
outputs |
inputs |
communicaiton |
(SUB) |
96x96mm. |
Basic control |
1-loop standard control |
2 points: Pulse voltage and Pulse voltage/current |
4 |
2 |
NO |
E5AR-Q4B |
|
(1 loop) |
Single loop heating and cooling control |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 points: Current and Current |
|
|
|
E5AR-C4B |
|
|
|
|
|
|
|
|
|
|
2 points: Pulse voltage and Pulse voltage/current |
|
|
RS-485 |
E5AR-Q43B-FLK |
|
|
|
|
|
|
(See note 2.) |
|
|
|
|
|
|
|
|
|
|
2 points: Current and Current |
|
|
|
E5AR-C43B-FLK |
|
|
|
|
|
|
(See note 2.) |
|
|
|
2 points: Pulse voltage and Pulse voltage/current |
|
6 |
|
E5AR-Q43DB-FLK |
|
|
|
|
|
|
(See note 2.) |
|
|
|
|
|
|
|
|
|
|
2 points: Current and Current |
|
|
|
E5AR-C43DB-FLK |
|
|
|
|
|
|
(See note 2.) |
|
|
|
4 points: Pulse voltage and Pulse voltage/current and Current (2 point) |
|
|
|
E5AR-QC43DB-FLK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2-loop control |
2-loop standard control |
2 points: Pulse voltage and Pulse voltage/current |
4 |
4 |
RS-485 |
E5AR-Q43DW-FLK |
|
|
Single-loop heating and cooling control |
|
|
|
(See note 2.) |
|
|
Single-loop cascade control |
|
|
|
|
|
|
Single-loop control with remote SP |
2 points: Current and Current |
|
|
|
E5AR-C43DW-FLK |
|
|
Single-loop proportional control |
|
|
|
(See note 2.) |
|
|
2-loop standard control |
4 points: Pulse voltage (2 point) and Pulse voltage/current (2 point) |
|
|
|
E5AR-QQ43DW-FLK |
|
|
Single-loop heating and cooling control |
|
|
|
|
|
|
Single-loop cascade control |
|
|
|
|
|
|
Single-loop control with remote SP |
|
|
|
|
|
|
Single-loop proportional control |
|
|
|
|
|
4-loop control |
4-loop standard control |
4 points: Current output (4 points) |
4 |
4 |
RS-485 |
E5AR-CC43DWW-FLK |
|
|
2-loop heating and cooling control |
|
|
|
|
|
|
|
4 points: Pulse voltage (2 point) and Pulse voltage/current (2 point) |
|
|
|
E5AR-QQ43DWW-FLK |
|
|
|
|
|
|
(See note 2.) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Position-proportional control |
Single loop position-proportional control |
Relay output |
4 |
4 |
NO |
E5AR-PR4DF |
|
(See note 3.) |
(1 open, 1 close) |
|
|
|
|
|
|
Relay output |
|
|
RS-485 |
E5AR-PRQ43DF-FLK |
|
(1 loop) |
|
(1 open, 1 close) |
|
|
|
|
|
|
|
and current (transfer) |
|
|
|
|
|
|
|
output |
|
|
|
|
Note. |
1: Specify the power supply specification when ordering. Model numbers for 100 to 240 VAC are difference from those for 24VAC/VDC. |
|
2: These models are for 100 to 240VAC only. |
|
|
|
3: Can be switched between close control and floating control. |
|
|
|
|
DeviceNet-Compatible Controllers |
Size |
Control type |
Control mode |
Outputs |
Optinal functions |
Model |
(control/transfer) |
Auxilary |
Event |
Serial |
outputs |
inputs |
communicaiton |
(SUB) |
96x96mm. |
Basic control |
1-loop standard control |
2 points: Pulse voltage and Pulse voltage/current |
4 |
2 |
YES |
E5AR-Q4B-DRT |
|
(1 loop) |
Single loop heating and cooling control |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 points: Current and Current |
|
|
|
E5AR-C4B-DRT |
|
|
|
|
|
|
|
|
|
|
4 points: Pulse voltage and Pulse voltage/current and Current (2 point) |
|
|
|
E5AR-QC4B-DRT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2-loop control |
2-loop standard control |
4 points: Pulse voltage (2 point) and Pulse voltage/current (2 point) |
4 |
NONE |
YES |
E5AR-QQ4W-DRT |
|
|
Single-loop heating and cooling control |
|
|
|
|
|
|
Single-loop cascade control |
|
|
|
|
|
|
Single-loop control with remote SP |
|
|
|
|
|
|
Single-loop proportional control |
|
|
|
|
|
4-loop control |
4-loop standard control |
4 points: Current output (4 points) |
4 |
NONE |
YES |
E5AR-CC4WW-DRT |
|
|
2-loop heating and cooling control |
|
|
|
|
|
Position-proportional control |
Single loop position-proportional control |
Relay output |
4 |
NONE |
YES |
E5AR-PR4F-DRT |
|
(See note 2.) |
(1 open, 1 close) |
|
|
|
|
|
|
Relay output |
|
|
|
E5AR-PRQ4F-DRT |
|
(1 loop) |
|
(1 open, 1 close) |
|
|
|
|
|
|
|
and current (transfer) |
|
|
|
|
|
|
|
output |
|
|
|
|
Note. |
1: Specify the power supply specification when ordering. Model numbers for 100 to 240 VAC are difference from those for 24VAC/VDC. |
|
3: Can be switched between close control and floating control. |
|
|
|
|